Hydrogen Bulk Gas Purifier - PS7-G - Getter Bed Only
(6.0N Hydrogen Required)

The getter only Hydrogen Purifier is ideal for facilities that have a 6.0N (99.9999%) quality hydrogen supply, and require N2 and CH4 removal.

The MegaTorr PS7-G Series Heated Getter Hydrogen Gas purifiers utilize a heated getter process to provide ultra-high purity (UHP) gas. This simplified approach provides outlet impurity levels to < 1 ppb for O2, CO, CO2, H2O, CH4, and N2. Getter column replacement can be performed in the field by an authorized SAES Field Service Engineer. The getter bed only Hydrogen Purifier requires 6.0N H2 (99.9999%). If your quality is lower than 6.0N please see the Adsorber and Getter Hydrogen Purifier.

Standard Features

  • Automated Microprocessor Controller
  • HMI (Human Machine Interface)
  • Password Protected Control System
  • System Alarms
  • Temperature Interlocks
  • Purged Secondary Enclosure
  • Leak Detection Sensor
  • Vented Cabinet Purge
  • Over Pressurization Safety Relief System
  • Electric Gas Preheater
  • Dual Closed-Loop Temperature Controls
  • Redundant Heating Elements
  • Pressure Transducers
  • Battery Back-up
  • Back-up Pneumatics Reservoir
  • Water Cooled Heat Exchanger
  • All Metal Enclosure With Doors

Optional Features

  • Auto or Manual Bypass
  • Mass flow meter with 4-20mA Output
  • Separate Control Power
  • UPS - Uninterruptible Power Supply
  • MODBUS Data Communication Port

 

PS7 Getter Only - Performance
Gas Purified Impurities Removed Outlet Performance
H2 H2O, O2, CO, CO2, N2 < 1 ppb
CH4, NMHC < 10 ppb (at factory), <1 ppb (on-site)
Note: Purifiers are gas specific and should only be used for the gas indicated
Purifier Lifetime Information
PS7 Getter Only - Specification
 Model Maximum Flow
(Nm3/hr)
Average Power
Consumption (kW)
Maximum Pressure
Drop (bar)
Dimensions (cm) Weight
(kg)
H W D
 PS7-MGT10-H-G 10 1.9 0.7 205 118 120 772
 PS7-MGT20-H-G 20 3.8 0.7 205 118 120 772
 PS7-MGT40-H-G 40 7.5 0.9 205 118 120 772
 PS7-MGT100-H-G 100 20.5 1 213 134 164 998

For outdoor installation see our outdoor enclosure options (OPAL)
Factory regenerable bulk gas purifiers, PS14

Applications

  • » Semiconductor
  • » LED
  • » Flat Panel Display
  • » Research
  • » Emerging Industries
  • » Industrial

Products

  • » Gas Purifiers
  • » Purifier Selection
  • » AMC Certification

Technical Support

  • » Contact Tech Support
  • » Purifier Regeneration
SAES
©2017 SAES Pure Gas, Inc. All rights reserved.
Site Map || Contact Us