Many of our MicroTorr ambient temperature purifiers are regenerable. Regenerable means that the impurities inside the purifier are removed. Once a regeneration is performed on the purifier it has an identical lifetime as if it was a new purifier. The Regeneration process takes approximately 6-8 weeks from the day the purifier is received at the factory.

The Regeneration Process

Step 1: Is your purifier regenerable? Please consult the chart below to see if your purifier is regenerable. The media refers to the three digit number located in the part number of the purifier. For example the purifier MC1-902F contains 902 media which is regenerable.

Media

example: MC3000-XXXF

Is it Regenerable (Yes/No)

Is it Dangerous Goods (Yes/No)

202

Yes

No

203

Yes

No

206

Yes

No

302

No

No

402

No

No

403

No

No

404

Yes

No

502

No

No

602

No 

Yes [UN2881, Class 4.2]

702

Yes

Yes [UN3089, Class 4.1]

703

Yes

Yes [UN3089, Class 4.1]

802

No

Yes [UN3089, Class 4.1]

804

Yes

Yes [UN2881, Class 4.2]

902

Yes

Yes [UN2881, Class 4.2]

903

Yes

Yes [UN2881, Class 4.2]

904

Yes

Yes [UN2881, Class 4.2]

905

Yes

Yes [UN2881, Class 4.2]

906

Yes

No


Step 2: Is your purifier classified as Dangerous Goods? Understanding if your purifier is Dangerous Goods (DG) is important because DG items must be shipped by someone certified to ship DG. This person will have attended classes on DG and has the relevant certification.

If the purifier is DG, please also provide the following information along with your request for an RMA#:

  • Copy of Shipper’s Declaration of Dangerous Goods (REQUIRED for ALL Air and Ocean Shipments)
  • Copy of DG Training Certificate for person signing Shipper’s Declaration of Dangerous Goods.
  • Copy of Declaration of Contamination Form

Step 3: Fill out the RMA paperwork (click here) - All product returned to SAES Pure Gas requires a Return Material Authorization (RMA). All regenerations are processed through the customer service department at SAES Pure Gas. Please fill out the information located on this page of our website (click here). Please provide the information on that webpage and download the Declaration of Contamination form. Please contact our Customer Service Department if you have any questions:

SAES Pure Gas Field Service Engineers

  • gp.fse@entegris.com
  • International: +1 (805) 781-2392
  • USA: 1 (800) 934-3628

Applications

  • » Semiconductor
  • » LED
  • » Flat Panel Display
  • » Research
  • » Emerging Industries
  • » Industrial

Products

  • » Gas Purifiers
  • » Purifier Selection
  • » AMC Certification

Technical Support

  • » Contact Tech Support
  • » Purifier Regeneration
SAES
©2017 SAES Pure Gas, Inc. All rights reserved.